The
equipment is designed and developed for
testing the SC VALVES & DOMESTIC LPG
regulators as per IS:8737 1995 & IS:9798:
1995 respectively.
The equipment is designed to conduct low
pressure tests at900mm, 1000mm & 1500mm
water column test pressure and high pressure
of 17 kg/sq.cm. The equipment can also be
used as production test bench to test the
SC VALVES as per IS : 8737 :1995 |
| |
| |
|
|
COMPACT
VALVE TESTER the instrument is highly
sensitive and can detect the leakage
of LPG up to 0.5 gm/hr within 3sec.
Of time.
The instrument is designed to check
both the possible leakage regarding
the SC valve fitted on Domestic
LPG cylinder. The probable leakages
are:
The leakage of LPG from the spindle
of valve and the probable leakage
through the joint seal fitted in
between the SC valve and regulator,
after the fittment of regulator.
|
|
| |
CVT
SYSTEM system is designed to test
the Sc valves fitted on domestic
LPG cylinder after filling. The
system is designed to detect the
leak on-line.
The system stop/holds the first
incoming cylinder on conveyor. The
operator then lowers the CVT on
the SC valve and press the pneumatic
foot valve. After preset time the
system will automatically declamp
and release the CVT. The system
will then release the tested LPG
cylinder and the cycle will be repeated
for next incoming LPG cylinder.
|
|
|
|
| |
|
|
The
COMPACT VALVE TESTER VERIFIER has
been designed and developed for
checking the sensitivity of COMPACT
VALVE TESTER to detect a rate of
leakage of the order of 0.5gm/hr
|
|
| |
AUTOMATION
FOR MECHANICAL WEIGH SCALE
It is the automation of mechanical
weigh scale achieved pneumatically.
The operator has to place the empty
LPG cylinder on the weigh scales,
set the required gross weight, lower
the hung pneumatic filling head
on the valve, and press the pneumatic
valve to give the 'ON' signal to
the system. The system will automatically
stop the filling of LPG and release
the filling head after the preset
weight is filled. |
|
|
|
| |
|
|
AUTO-HEAT
SEALING SYSTEM
System is designed to heat seal
the PVC - seals on the domestic
cylinder valves, on-line. The system
is totally pneumatic and automatic.
The system is installed along the
side of the conveyor. The first
incoming cylinder is sensed and
hold by the system.
The steam cup starts moving down,
while the LPG cylinder is still
moving, overlapping the horizontal
movement of LPG cylinder before
it stops.
The steam valve gets opened as the
steam cup senses the top of the
LPG cylinder and the entire assembly
of steam cup, steam valve retracts.
The LPG cylinder is released. The
system is now ready to heat seal
the next incoming cylinder.
The capacity of the system is to
heat seal about 1,200 cylinders
per hour |
|